Related Experiment Video
Updated: Nov 14, 2025

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Smartphone Thermal Imaging in the Detection of Testicular Ischemia
J Patrick Brooks1, Jake M Brooks1, Tora Seals1
1Missouri State University, Springfield, MO.
Objective:
To evaluate smartphone thermal imaging as a point of care test in the detection of testicular ischemia. Thermal imaging detects the infrared (heat) pattern of an object and the technology is now available as an inexpensive attachment to smartphones.
Materials And Methods:
Smartphone thermal imaging was studied as a point-of-care diagnostic test for testicular ischemia in an IACUC approved study that prioritized survival of all animal subjects. Thirty canines weighing over 12 kg were observed during elective neuter procedures with consent from owners. Randomization determined ligation of the right vs left spermatic cord. With both testicles remaining in the scrotum, blinded inspection was performed with a FLIR ONE Pro thermal imaging camera for smartphone use. The bilateral orchiectomy procedures were then completed as planned.
Results:
Within 11 minutes of ligation of the randomized spermatic cord, an obvious change in the thermal imaging pattern allowed for the correct diagnosis of the ischemic testicle in 30/30 (100%) of subjects in a blinded fashion. Temperature differences between testicles at the time of ischemia diagnosis ranged from 0.7°C to 3.7°C with an average difference of 1.79°C lower in the ischemic testicle (95% CI: [1.50, 2.08]). A thermal imaging evaluation of the testicles takes 30 seconds to perform.
Conclusion:
Smartphone thermal imaging correctly diagnosed testicular ischemia in 100% of animal subjects in a blinded fashion. The clinical utility of this emerging point-of-care technique in the evaluation of testicular torsion is currently unknown.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...