Novel Dual-Lumen Drainage Catheter to Enhance the Active Evacuation of Complex Fluid Collections
Dustin G Roberts1, Marcus J Goudie2, Alexander J Kim3
1David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California; Division of Interventional Radiology, Department of Radiology, University of California, Los Angeles, Los Angeles, California.
Purpose:
To compare the performance of a dual-lumen flushable drainage catheter to a conventional catheter for complex fluid collection drainage.
Methods:
Two prototype catheters (20- and 28-F) were created by incorporating a customized infusion lumen within the wall of a large-bore conventional drainage catheter, which facilitated simultaneous irrigation of the drainage lumen and the targeted collection via inward- and outward-facing infusion side holes. These were tested against unaltered 20- and 28-F conventional catheters to determine if the injection of a dedicated flush lumen improved rapidity and completeness of gravity drainage. In vitro models were created to simulate serous fluid, purulent/exudative fluid, particulate debris, and acute hematoma.
Results:
In the purulent model, mean drainage rate was 19.9 ± 8.0 and 9.5±1.4 mL/min for the 20-F prototype and control (P < .001) and 63.9 ± 4.3 and 35.4 ± 3.4 mL/min for the 28-F prototype and control (P = .006), respectively, with complete drainage achieved in all trials. In the particulate model, mean drainage rate was 24.5 ± 9.7 and 12.0 ± 12.5 mL/min for the 28-F prototype and control (P = .003), respectively, with 69.0% versus 41.1% total drainage achieved over 24 minutes (P = .029). In the hematoma model, mean drainage rate was 22.7 ± 4.6 and 4.8 ± 4.3 mL/min for the 28-F prototype and control (P = .022), respectively, with 80.3% versus 20.1% drainage achieved over 15 minutes (P = .003). Particulate and hematoma 20-F prototypes and conventional trials failed due to immediate occlusion.
Conclusions:
The proposed dual-lumen drainage catheter with irrigation of a dedicated flush lumen improved evacuation of complex fluid collections in vitro.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Suctioning II: Procedure
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Aneurysm IV: Nursing Management