Related Experiment Video
Updated: Nov 14, 2025

Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Concentration and pressure scaling of CH2O electronic-resonance-enhanced coherent anti-Stokes Raman scattering
Abstract:
Nanosecond electronic-resonance-enhanced coherent anti-Stokes Raman scattering (ERE-CARS) is evaluated for the measurement of formaldehyde (CH2O) concentrations in reacting and nonreacting conditions. The three-color scheme utilizes a 532 nm pump beam and a scanned Stokes beam near 624 nm for Raman excitation of the C-H symmetric stretch (ν1) vibrational mode; further, a 342 nm resonant probe is tuned to produce the outgoing CARS signal via the 101403 vibronic transition between the ground (X~1A1) and first excited (A~1A2) electronic states. This allows detection of CH2O at concentrations as low as 9×1014molecules/cm3 (55 parts per million) in a calibration cell with CH2O and N2 at 1 bar and 450 K with 3% uncertainty. The measurements show a quadratic dependence of the signal with CH2O number density. Pressure scaling experiments up to 11 bar in the calibration cell show an increase in signal up to 8 bar. We study pressure dependence up to 11 bar and further apply the technique to characterize the CH2O concentration in an atmospheric premixed dimethyl ether/air McKenna burner flame, with a maximum concentration uncertainty of 11%. This approach demonstrates the feasibility for spatially resolved measurements of minor species such as CH2O in reactive environments and shows promise for application in high-pressure combustors.
More Related Videos
09:46Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
12:56Differential Imaging of Biological Structures with Doubly-resonant Coherent Anti-stokes Raman Scattering CARS
Published on: October 17, 2010
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)