High-accuracy and rapid azimuth calibration for polarizing elements in ellipsometry by differential spectral analysis

Applied Optics
|March 10, 2021
PubMed

Related Concept Videos

Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical...
27.0K
Polar Equations of Conics01:29

Polar Equations of Conics

A conic section can be defined in polar coordinates as the set of all points whose distance from a fixed point, known as the focus, bears a constant ratio to their distance from a fixed line, known as the directrix. This constant ratio is called the eccentricity. This definition unifies all types of conic sections—ellipses, parabolas, and hyperbolas—under a single framework. When the focus is positioned at the origin of the polar coordinate system, a single polar equation can describe any...
56
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
451
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
383
Graphs of Polar Equations01:17

Graphs of Polar Equations

The polar coordinate system represents points using a distance from a central point (the pole) and an angle from a reference direction (the polar axis). Unlike rectangular coordinates, polar coordinates are ideal for graphing curves with radial symmetry or periodic behavior.Some general forms of graphs in polar coordinates include the following:Equation of a Circle (Centered at the Pole):A graph where the radius remains constant for all angles traces a circle centered at the pole:Equation of a...
83
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
709