Intelligent Oscillometric System for Automatic Detection of Peripheral Arterial Disease
Abstract:
Peripheral arterial disease (PAD) is a progressing arterial disorder that is associated with significant morbidity and mortality. The conventional PAD detection methods are invasive, cumbersome, or require expensive equipment and highly trained technicians. Here, we propose a new automated, noninvasive, and easy-to-use method for the detection of PAD based on characterizing the arterial system by applying an external varying pressure using a cuff. The superposition of the internal arterial pressure and the externally applied pressure were measured and mathematically modeled as a function of cuff pressure. A feature-based learning algorithm was then designed to identify PAD patterns by analyzing the parameters of the derived mathematical models. Genetic algorithm and principal component analysis were employed to select the best predictive features distinguishing PAD patterns from normal. A RUSBoost ensemble model using neural network as the base learner was designed to diagnose PAD from genetic algorithm selected features. The proposed method was validated on data collected from 14 PAD patients and 19 healthy individuals. It achieved a high accuracy, sensitivity, and specificity of 91.4%, 90.0%, and 92.1%, respectively, in detecting PAD. The effect of age, a confounding factor that may have impacted our analyzes, was not considered in this study. The proposed method shows promise toward noninvasive and accurate detection of PAD and can be integrated into routine oscillometric blood pressure measurements.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease I: Introduction
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure in the Leg
Preparation:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: