Aim:
To evaluate the utility of noninvasive electrocardiometry (ICON®) for hemodynamic categorization and assessment of fluid responsiveness in pediatric septic shock.
Materials And Methods:
Pilot prospective observational study in a 12-bedded tertiary pediatric intensive care unit (PICU) in children aged between 2 months and 16 years with unresolved septic shock after a 20 mL/kg fluid bolus. Those with cardiac index (CI) <3.3 L/min/m2 and systemic vascular resistance index (SVRI) >1600 dyn sec/cm5/m2 were classified as vasoconstrictive shock-electrocardiometry (VCEC) and those with CI >5.5 L/min/m2 and SVRI <1000 dyn sec/cm5/m2 as vasodilated shock-electrocardiometry (VDEC). Fluid responsiveness was defined as a 10% increase in CI with a 20 mL/kg fluid bolus. Sepsis-induced myocardial dysfunction (SMD) was diagnosed on echocardiography. Outcomes studied included clinical shock resolution, length of PICU stay, and mortality.
Results:
Thirty children were enrolled over 6 months with a median (interquartile range) age and pediatric risk of mortality (PRISM) III score of 87(21,108) months and 6.75(1.5,8.25), respectively; 14(46.6%) were boys and 4(13.3%) died. Clinically, 19(63.3%) children had cold shock and 11(36.7%) had warm shock; however, 16(53.3%) children had VDEC (including five with clinical cold shock) and 14(46.7%) had VCEC using electrocardiometry. Fluid responsiveness was seen in 16(53.3%) children, 10 in the VCEC group and 6 in the VDEC group. In the VCEC group, the responders had a significant rise in CI and a fall in SVRI, while the responders in the VDEC group had a significant rise in CI and SVRI. Fluid responders, compared to nonresponders, had a significantly higher stroke volume variation (SVV) before fluid bolus (24.1 ± 5.2% vs. 18.2 ± 3.5%, p < 0.001) and a higher reduction in SVV after fluid bolus (10.0 ± 2.8% vs. 6.0 ± 4.5%, p = 0.006), higher lactate clearance (p = 0.03) and lower vasoactive-inotropic score (p = 0.04) at 6 hours, higher percentage of clinical shock resolution at 6 (p = 0.01) and 12 hours (p = 0.01), and lesser mortality (p = 0.002). Five (16.6%) children with VCEC had SMD and were less fluid responsive (p = 0.04) with higher mortality (p = 0.01) compared to those without SMD.
Conclusions And Clinical Significance:
Continuous, noninvasive hemodynamic monitoring using electrocardiometry permits hemodynamic categorization and assessment of fluid responsiveness in pediatric septic shock. This may provide real-time guidance for optimal interventions, and thus, improve the outcomes.
How To Cite This Article:
Rao SS, Reddy M, Lalitha AV, Ghosh S. Electrocardiometry for Hemodynamic Categorization and Assessment of Fluid Responsiveness in Pediatric Septic Shock: A Pilot Observational Study. Indian J Crit Care Med 2021;25(2):185-192.
Related Concept Videos
Heart Failure IV: Classification and Diagnostic Evaluation
Cardiopulmonary Resuscitation IV: Pharmacological Management
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Dysrhythmias V: Evaluating Dysrhythmias