Background:
Several deep learning-based techniques have been developed for prostate cancer (PCa) detection using multiparametric magnetic resonance imaging (mpMRI), but few of them have been rigorously evaluated relative to radiologists' performance or whole-mount histopathology (WMHP).
Purpose:
To compare the performance of a previously proposed deep learning algorithm, FocalNet, and expert radiologists in the detection of PCa on mpMRI with WMHP as the reference.
Study Type:
Retrospective, single-center study.
Subjects:
A total of 553 patients (development cohort: 427 patients; evaluation cohort: 126 patients) who underwent 3-T mpMRI prior to radical prostatectomy from October 2010 to February 2018.
Field Strength/Sequence:
3-T, T2-weighted imaging and diffusion-weighted imaging.
Assessment:
FocalNet was trained on the development cohort to predict PCa locations by detection points, with a confidence value for each point, on the evaluation cohort. Four fellowship-trained genitourinary (GU) radiologists independently evaluated the evaluation cohort to detect suspicious PCa foci, annotate detection point locations, and assign a five-point suspicion score (1: least suspicious, 5: most suspicious) for each annotated detection point. The PCa detection performance of FocalNet and radiologists were evaluated by the lesion detection sensitivity vs. the number of false-positive detections at different thresholds on suspicion scores. Clinically significant lesions: Gleason Group (GG) ≥ 2 or pathological size ≥ 10 mm. Index lesions: the highest GG and the largest pathological size (secondary).
Statistical Tests:
Bootstrap hypothesis test for the detection sensitivity between radiologists and FocalNet.
Results:
For the overall differential detection sensitivity, FocalNet was 5.1% and 4.7% below the radiologists for clinically significant and index lesions, respectively; however, the differences were not statistically significant (P = 0.413 and P = 0.282, respectively).
Data Conclusion:
FocalNet achieved slightly lower but not statistically significant PCa detection performance compared with GU radiologists. Compared with radiologists, FocalNet demonstrated similar detection performance for a highly sensitive setting (suspicion score ≥ 1) or a highly specific setting (suspicion score = 5), while lower performance in between.
Level Of Evidence:
3 TECHNICAL EFFICACY STAGE: 2.