X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Impact of a contrast-to-noise ratio driven and material specific exposure control on image quality and radiation
Thomas Werncke1, Marius Kemling1, Stanislav Tashenov2
1Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, D-30625 Hannover, Germany.
Abstract:
Conventional detector-dose driven exposure controls (DEC) do not consider the contrasting material of interest in angiography. Considering the latter when choosing the acquisition parameters should allow for optimization of x-ray quality and consecutively lead to a substantial reduction of radiation exposure. Therefore, the impact of a material-specific, contrast-to-noise ratio (CNR) driven exposure control (CEC) compared to DEC on radiation exposure was investigated. A 3D-printed phantom containing iron, tantalum, and platinum foils and cavities, filled with iodine, barium, and gas (carbon dioxide), was developed to measure the CNR. This phantom was placed within a stack of polymethylmethacrylate and aluminum plates simulating a patient equivalent thickness (PET) of 2.5-40 cm. Fluoroscopy and digital radiography (DR) were conducted applying either CEC or three, regular DEC protocols with parameter settings used in abdominal interventions. CEC protocols where chosen to achieve material-specific CNR values similar to those of DEC. Incident air kerma at the reference point(Ka,r), using either CEC or DEC, was assessed and possible Ka,r reduction for similar CNR was estimated. We show that CEC provided similar CNR as DEC at the same or lower Ka,r. When imaging barium, iron, and iodine Ka,r was substantially reduced below a PET of 20 cm and between 25 cm and 30 cm for fluoroscopy and Dr When imaging platinum and tantalum using fluoroscopy and DR and gas using DR, the Ka,r reduction was substantially higher. We estimate the Ka,r reduction for these materials between 15% and 84% for fluoroscopy and DR between 15% and 93% depending on the PET. The results of this study demonstrate a high potential for skin dose reduction in abdominal radiology when using a material-specific CEC compared to DEC. This effect is substantial in imaging materials with higher energy K-edges, which is beneficial, for example, in long-lasting embolization procedures with tantalum-based embolization material in young patients with arterio-venous malformations.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging