Related Experiment Video
Updated: Nov 13, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Use of high resolution/accurate mass full scan/data-dependent acquisition for targeted/non-targeted screening in
Youwen You1, Rachel M Proctor, Kevin Guo
1Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, Kennett Square, PA 19348, USA. ywyou@upenn.edu.
Abstract:
High-resolution mass spectrometry (HRMS) is a very powerful technology for equine doping control analysis. The more recently developed hybrid type of Orbitrap-based HRMS instrument allows for both targeted and non-targeted screening analyses in a single liquid chromatography-high resolution tandem mass spectrometry (LC-HRMS/MS) run. In the present study, an LC-HRMS/MS method was developed and validated to detect prohibited substances in equine sports. The substances were recovered from equine plasma by liquid-liquid extraction (LLE) using methyl tert-butyl ether and were separated on a C18 reversed-phase column using mobile phases of 5 mM ammonium formate and acetonitrile. A 7.5 min LC gradient was employed to elute substances and results indicated that the LC method generated sharp and symmetric chromatographic peaks. An in-house equine doping compound database and a spectral library were built to increase method specificity for substances of interest. Five criteria, i.e. accurate mass, retention time, isotope pattern, selected HRMS/MS fragment ions (compound database) and HRMS/MS spectra (spectral library), were employed for targeted screening. We utilized these criteria to validate targeted detection of 451 substances within our in-house equine doping compound database. By using all five criteria in screening, the false screening positive rate is significantly reduced. A screening strategy and a Microsoft Excel macro were developed to facilitate interpretation and reporting of results. As the simultaneous acquisition of the full scan HRMS data provides the opportunity for retrospective non-targeted analysis, our findings highlight the use of this novel methodology as a simple, rapid, and reliably reproducible strategy to meet the challenge of identifying an increasing number of doping substances that could potentially impact the integrity of the horse racing community.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Resolution Mass Spectrometry (HRMS)
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors