Locking plate combined with titanium cable for Neer type II distal clavicle fractures
Fan Zhang1, Qiang Fu1, Yongchuan Li1
1Department of Orthopaedics, Changzheng Hospital, Second Military Medical University, 415# Fengyang Road, Huangpu District,, 200003, Shanghai, China.
Background:
There is controversy about the optimal strategy treatment of unstable distal clavicle fractures. We explored use of a surgical strategy: combination of a distal clavicle locking plate and a titanium cable. The purpose of this retrospective case series study was to evaluate the clinical outcomes of this new strategy in treating Neer type II distal clavicle fractures.
Methods:
Twenty-one patients with Neer type II distal clavicle fracture were treated with a distal clavicle locking plate and a titanium cable. All patients were followed for at least one year. We retrospectively collected and reviewed follow-up data. The clinical outcomes were assessed for union rate, functional score, and complication rate.
Results:
All patients achieved bony union within 6 months. The average follow-up period was 20.6 months (range12-48 months). The mean Constant score at one-year follow-up was 94.6 ± 3.3 (range 84-98), and the mean UCLA (University of California, Los Angeles) score was 33.3 ± 2.6 (range 27-35). Only one complication (wound infection) was observed during follow-up. Two patients received another operation for implant removal due to local irritation.
Conclusions:
Use of a distal clavicle locking plate in combination with a titanium cable for treatment of Neer type II fractures results in high union rate, a low complication rate, and good shoulder function. This combined surgical strategy can be considered an effective method for treating unstable distal clavicle fractures.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...