Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Inter-reader reliability of CT Liver Imaging Reporting and Data System according to imaging analysis methodology: a
Ji Hun Kang1, Sang Hyun Choi2, Ji Sung Lee3,4
1Department of Radiology, Hanyang University College of Medicine, Hanyang University Guri Hospital, Guri-si, Gyeonggi-do, Republic of Korea.
Objectives:
To establish inter-reader reliability of CT Liver Imaging Reporting and Data System (LI-RADS) and explore factors that affect it.
Methods:
MEDLINE and EMBASE databases were searched from January 2014 to March 2020 to identify original articles reporting the inter-reader reliability of CT LI-RADS. The imaging analysis methodology of each study was identified, and pooled intraclass correlation coefficient (ICC) or kappa values (κ) were calculated for lesion size, major features (arterial-phase hyperenhancement [APHE], nonperipheral washout [WO], and enhancing capsule [EC]), and LI-RADS categorization (LR) using random-effects models. Subgroup analyses of pooled κ were performed for the number of readers, average reader experience, differences in reader experience, and LI-RADS version.
Results:
In the 12 included studies, the pooled ICC or κ of lesion size, APHE, WO, EC, and LR were 0.99 (0.96-1.00), 0.69 (0.58-0.81), 0.67 (0.53-0.82), 0.65 (0.54-0.76), and 0.70 (0.59-0.82), respectively. The experience and number of readers varied: studies using readers with ≥ 10 years of experience showed significantly higher κ for LR (0.82 vs. 0.45, p = 0.01) than those with < 10 years of reader experience. Studies with multiple readers including inexperienced readers showed significantly lower κ for APHE (0.55 vs. 0.76, p = 0.04) and LR (0.45 vs. 0.79, p = 0.02) than those with all experienced readers.
Conclusions:
CT LI-RADS showed substantial inter-reader reliability for major features and LR. Inter-reader reliability differed significantly according to average reader experience and differences in reader experience. Reported results for inter-reader reliability of CT LI-RADS should be understood with consideration of the imaging analysis methodology.
Key Points:
• The CT Liver Imaging Reporting and Data System (LI-RADS) provides substantial inter-reader reliability for three major features and category assignment. • The imaging analysis methodology varied across studies. • The inter-reader reliability of CT LI-RADS differed significantly according to the average reader experience and the difference in reader experience.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...