Related Experiment Video
Updated: Nov 13, 2025
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)
Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
Utility of non-contrast head computed tomography in poisoned patients
Richard McNulty1,2,3, Lashnika Bandaranayake3, Timothy Wong3
1Department of Emergency Medicine, Blacktown and Mount Druitt Hospitals, Sydney, New South Wales, Australia.
Objective:
To investigate the utility of non-contrast head computed tomography (CT) in poisoned patients.
Methods:
A retrospective cohort study of patients referred to a toxicology unit between August 2010 and December 2017. Our database yielded patients who underwent head CT at presentation to the ED. Pre-specified information was compiled from the medical records.
Results:
There were 6261 presentations of which 1142 underwent head CT (17%). Median age was 41 years, and 437 (38%) were female. There were 492 (43%) recreational ingestions and 466 (41%) deliberate self-poisonings. The commonest agents were sedatives 376 (33%) and opioids 282 (24%); 334 (29%) cases were intubated. Signs of head injury were found in 153 cases (13%) and focal neurological signs in 68 (6%). No acute pathology was reported in 884 head CTs (77%), chronic changes in 193 (17%) and incidental findings in 26 (2%). Acute pathology was found in 39 (4%) patients: 15 with hypoxic-ischaemic injury, three infarctions, nine with intra-cranial haemorrhage, 11 facial bone fractures and one retro-bulbar haematoma. No patient required an immediate surgical intervention, and only one patient had a change to clinical treatment. Acute head CT pathology was associated with at least one of the following clinical features: need for intubation, signs of head injury, seizure, headache, and unexpected neurological signs.
Conclusion:
Non-contrast head CT is a low-yield investigation in patients presenting with poisoning. Consideration should be given as to whether the clinical presentation is consistent with the expected toxidrome and whether the patient would benefit from head CT.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET