Related Experiment Video
Updated: Nov 13, 2025

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Improving practice in radiology: a quality-improvement project examining CT colonography patient dose and scanning
G R Iball1, D Tolan2, G R Avery3
1Department of Medical Physics, Old Medical School, Leeds General Infirmary, Leeds, LS1 3EX, UK.
Aim:
To audit scanning technique and patient doses for computed tomography (CT) colonography (CTC) examinations in a large UK region and to identify opportunities for quality improvement.
Materials And Methods:
Scanning technique and patient dose data were gathered for both contrast-enhanced and unenhanced CTC examinations from 33 imaging protocols across 27 scanners. Measurements of patient weight and effective diameter were also obtained. Imaging protocols were compared to identify technique differences between similar scanners. Scanner average doses were calculated and combined to generate regional diagnostic reference limits (DRLs) for both examinations.
Results:
The regional DRLs for contrast-enhanced examinations were volume CT dose index (CTDIvol) of 11 and 5 mGy for the two scan phases (contrast-enhanced and either delayed phase or non-contrast enhanced respectively), and dose-length product (DLP) of 740 mGy·cm. For unenhanced examinations, these were 5 mGy and 450 mGy·cm. These are notably lower than the national DRLs of 11 mGy and 950 mGy·cm. Substantial differences in scan technique and doses on similar scanners were identified as areas for quality-improvement action.
Conclusion:
A regional CTC dose audit has demonstrated compliance with national DRLs but marked variation in practice between sites for the dose delivered to patients, notably when scanners of the same type were compared for the same indication. This study demonstrates that the national DRL is too high for current scanner technology and should be revised.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT