Related Experiment Video
Updated: Nov 13, 2025

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Implementation of a Postoperative Electronic Health Record Alert for Cardiac Implantable Electronic Device Patients
Caroline Traczyk1, Andi N Rice2, Annemarie Thompson1
1Department of Anesthesia, Duke University Hospital, Durham, NC.
Purpose:
Approximately 2% of surgical patients have an existing cardiac implantable electronic device (CIED). Perioperative device reprogramming requires postoperative care to ensure that device settings are restored. Electronic health record (EHR) alerts have been shown to improve communication between providers and decrease time to necessary interventions in other areas of medicine. The aim of this quality improvement project was to create an EHR alert for postoperative CIED patients who require device reprogramming to help clinicians track, remember, and document the timely and safe restoration of device settings.
Design:
This project used a pre-post observational design.
Methods:
This project was conducted at a major academic medical center using a pre-post observational design. To prevent anesthesia providers from closing an encounter in the EHR before postoperative restoration of device settings, an alert was developed and embedded within the intraoperative EHR to track preoperative device reprogramming, and alert anesthesia providers to perform and document postoperative restoration of safe settings.
Findings:
The postimplementation group (n = 272) had fewer unknown or undocumented preoperative CIED interventions (12.9% vs 30.9%), a 7.3% shorter device suspension time (median = 165 minutes vs 178 minutes), 6.8% improvement in documentation of postoperative re-enabling of device therapies (78.8% vs 72.0%), and a 72.48% decrease in length of stay (median = 625 hours vs 172 hours) when compared with the preimplementation group (n = 132).
Conclusion:
Electronic prompts effectively captured patients who received preoperative CIED reprogramming and provided a process for reprogramming devices to safe settings, both significant steps in preventing negative patient outcomes associated with undocumented CIED interventions. Perioperative CIED documentation improved, and length of stay decreased after project implementation.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Cardiopulmonary Resuscitation III: AED Use
Cardiomyopathy V: Interprofessional Care
Methods of Documentation VII: EMR
Cardiomyopathy VII: Pre and Post Operative Nursing Management