Automated liquid-liquid extraction of organic compounds from aqueous samples using a multifunction autosampler
Masoomeh Tehranirokh1, Marcel Van den Bronk2, Peter Smith2
1ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75 Hobart, 7001 Australia; Trajan Scientific and Medical, 7 Argent Place Ringwood, 3134 Australia.
Abstract:
Liquid-liquid extraction is one of the most widely used and simplest sample preparation techniques. However, consumption of large volumes of organic solvent and manual handling are two major drawbacks of this technique. A multifunction autosampler syringe is introduced which permits automated liquid-liquid extraction in an enclosed operating environment, with low consumption of organic solvents. The device described herein features a micromixer function in addition to common autosampler syringe features like accurate and precise aspirating and dispensing. To test the functionality of the micromixer syringe, manual extraction of caffeine from a tea infusion and semi-automated extraction of dichloroethane from water were carried out. Excellent recoveries of caffeine from a tea infusion (89% recovery with 1.3% RSD) and dichloroethane from water (107% recovery with 10% RSD) were obtained. Two automated workflows were tested using the micromixer syringe mounted in a laboratory autosampler. Standalone automated micro liquid-liquid extraction was performed for sample preparation of selected polychlorinated biphenyl (PCB) congeners prior to comprehensive two-dimensional gas chromatography - electron capture detection analysis. Extraction of PCBs using the described approach used substantially less solvent than a validated solid-phase extraction approach whilst delivering equivalent results for samples with high-level PCBs. Finally, fully automated extraction and GC-MS analysis of polynuclear aromatic hydrocarbons (PAHs) from water samples was performed. Mean recoveries of extraction for PCB and PAH analysis were > 70% using 4 min automated liquid-liquid extractions.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
09:09Preparation of Human Tissues Embedded in Optimal Cutting Temperature Compound for Mass Spectrometry Analysis
Published on: April 27, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: