Related Experiment Video
Updated: Nov 13, 2025

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Dispersive liquid-liquid microextraction using a low transition temperature mixture and liquid chromatography-mass
Valeria Gallo1, Pierpaolo Tomai1, Monica Gherardi2
1Department of Chemistry, Sapienza University, P.le Aldo Moro 5, 00185, Rome Italy.
Abstract:
Biomonitoring is a potent tool to control the health risk of people occupationally and non-occupationally exposed. The latest trend in bioanalytical chemistry is to develop quick, cheap, easy, safe and reliable green analytical procedures to analyse a large number of chemicals in easily accessible biomatrices such as urine. In this paper, a new dispersive liquid-liquid microextraction (DLLME) procedure, conceived to treat urine samples and based on the use of a low transition temperature mixture (LTTM), was developed and validated to analyse twenty pesticides commonly used in farm practises. The LTTM was composed of choline chloride and sesamol in molar ratio 1:3 (ChCl:Ses 1:3); its characterization via differential scanning calorimetry identified it as an LTTM and not as a deep eutectic solvent due to the occurrence of a glass transition at -71 °C. The prepared mixture was used as the extraction solvent in the DLLME procedure, while ethyl acetate as the dispersing solvent. The salting out effect (50 mg mL-1 of NaCl in a diluted urine sample) improved the separation phase and the analyte transfer to the extractant. Due to the high ionic strength and despite the density of ChCl:Ses 1:3 (1.25 g mL-1), the LTTM layer floated on the top of the sample solution after centrifugation. All extracts were analysed by high-performance liquid chromatography coupled to mass spectrometry. After optimization and validation of the whole method, lower limits of quantitation were in the range of 0.02 - 0.76 µg L-1. Extraction recoveries spanned from 50 to 101 % depending on the spike level and analytes. Precision and accuracy ranges were 3-18% and 5-20%, respectively. The extraction procedure was also compared with other methods, showing to be advantageous for rapidity, simplicity, efficiency, and low cost. Finally, urine samples from ten volunteers were effectively analysed using the developed method.
More Related Videos
11:17A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample
Published on: June 1, 2017
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: