A Flow Cytometry-Based Cell Surface Protein Binding Assay for Assessing Selectivity and Specificity of an Anticancer Aptamer
Published on: September 13, 2022
PD-L1 aptamer isolation via Modular-SELEX and its applications in cancer cell detection and tumor tissue section
Jiyuan Li1, Xijiao Ren1, Jiaxing Zhao1
1Department of Chemistry, Capital Normal University, Xisanhuan North Road 105, Beijing 100048, China. xinhuilou@cnu.edu.cn.
Abstract:
PD-1/PD-L1 is an important pathway in immunotherapy and a high PD-L1 expression level in tumor tissues is an essential prerequisite for PD-1/PD-L1 blocking-based therapy. The PD-L1 expression level in tumor tissue sections is currently detected via immunohistochemistry (IHC) using anti-PD-L1 antibodies from various resources, which has the disadvantage of inconsistent results. As synthetic affinity ligands, aptamers have good batch-to-batch consistency and have been demonstrated to have great potential for use in biomedical applications. In this study, we isolated PD-L1 aptamers using a combination method, named Modular-SELEX (systematic evolution of ligands by exponential enrichment), which includes three sequentially performed modules: the affinity module, the specificity module, and the compatibility module. Three rounds of magnetic crosslinking precipitation (MCP)-SELEX, three rounds of Capture-SELEX, and two rounds of Tissue-SELEX were respectively performed in the corresponding three modules to significantly and efficiently improve the native affinity, specificity, and compatibility of the enriched library. The isolated aptamer Clon-3 had nanomolar binding affinity, as determined via both homogeneous and PD-L1 immobilized affinity assays. Clon-3 could be used to recognize various cancer cells with distinct PD-L1 expression levels using flow cytometry. The PD-L1 expression levels in normal human tonsils (the gold standard for anti-PD-L1 antibody) and non-small cell lung cancer tissue sections stained using Cy5.5-labeled Clon-3 were also successfully imaged using a confocal microscope. The fluorescence intensities of the tissue sections were in good agreement with their actual PD-L1 expression levels as confirmed via IHC.
More Related Videos
07:04Identifying PD-1/PD-L1 Inhibitors with Surface Plasmon Resonance Technology
Published on: May 2, 2025
06:05Author Spotlight: Multiplex Immunofluorescence Combined with Spatial Image Analysis for the Clinical and Biological Assessment of the Tumor Microenvironment
Published on: June 2, 2023