Related Experiment Video
Updated: Nov 12, 2025

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Atrial fibrillation is associated with large beat-to-beat variability in mitral and tricuspid annulus dimensions
Jwan A Naser1, Hilal Olgun Kucuk1, Andrea O Ciobanu2,3
1Department of Cardiovascular Medicine, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA.
Insights
Atrial fibrillation (Afib) causes greater beat-to-beat variability in mitral and tricuspid annulus size and timing than sinus rhythm. This finding is crucial for selecting percutaneous devices in patients with Afib and valve disease.
Area of Science:
- Cardiovascular Imaging
- Cardiac Electrophysiology
- Valvular Heart Disease
Background:
- Beat-to-beat variability in cardiac cycle length is a known characteristic of atrial fibrillation (Afib).
- The impact of Afib on the variability of mitral and tricuspid annulus size remains largely unexplored.
- Accurate assessment of annulus size is critical for percutaneous device selection, especially in patients with coexisting mitral and tricuspid valve disease.
Purpose of the Study:
- To investigate whether atrial fibrillation (Afib) influences the beat-to-beat variability of mitral annulus (MA) and tricuspid annulus (TA) size.
- To compare the variability in annulus size and the timing of maximal annulus size between patients in sinus rhythm (SR) and Afib.
- To provide data that can aid in the selection of percutaneous devices for valve interventions in patients with Afib.
Main Methods:
- Utilized 3D echocardiography to acquire images from 170 patients (100 for MA, 70 for TA), including subgroups in SR and Afib.
- Employed commercially available software to analyze annular dynamics and quantify the beat-to-beat variability in maximal annulus area over 4-6 cardiac cycles.
- Assessed the timing of maximal annulus size relative to the R-R interval in each analyzed cardiac cycle.
Main Results:
- Patients with Afib exhibited significantly greater beat-to-beat variability in maximal MA area (median absolute difference 1.8 cm²) compared to SR patients (0.8 cm²; P < 0.001).
- Similarly, Afib patients showed higher beat-to-beat variability in maximal TA area (1.4 cm²) than SR patients (0.7 cm²; P < 0.001).
- The timing of maximal annulus size demonstrated greater variability in Afib compared to SR for both MA and TA.
Conclusions:
- Both mitral and tricuspid annuli display significant beat-to-beat size variability, with maximal size occurring within a broad temporal range.
- Atrial fibrillation exacerbates this beat-to-beat variability in both the magnitude and timing of annulus size compared to sinus rhythm.
- These findings underscore the importance of considering dynamic annular changes in Afib when planning percutaneous device implantation.
Aims:
Beat-to-beat variability in cycle length is well-known in atrial fibrillation (Afib); whether this also translates to variability in annulus size remains unknown. Defining annulus maximal size in Afib is critical for accurate selection of percutaneous devices given the frequent association with mitral and tricuspid valve diseases.
Methods And Results:
Images were obtained from 170 patients undergoing 3D echocardiography [100 (50 sinus rhythm (SR) and 50 Afib) for mitral annulus (MA) and 70 (35 SR and 35 Afib) for tricuspid annulus (TA)]. Images were analysed for differences in annular dynamics with a commercially available software. Number of cardiac cycles analysed was 567 in mitral valve and 346 in tricuspid valve. Median absolute difference in maximal MA area over four to six cycles was 1.8 cm2 (range 0.5-5.2 cm2) in Afib vs. 0.8 cm2 (range 0.1-2.9 cm2) in SR, P < 0.001. Maximal MA area was observed within 30-70% of the R-R interval in 81% of cardiac cycles in SR and in 73% of cycles in Afib. Median absolute difference in maximal TA area over four to six cycles was 1.4 cm2 (range 0.5-3.6 cm2) in Afib vs. 0.7 cm2 (range 0.3-1.7 cm2) in SR, P < 0.001. Maximal TA area was observed within 60-100% of the R-R interval in 81% of cardiac cycles in SR, but only in 49% of cycles in Afib.
Conclusion:
MA and TA reach maximal size within a broad time interval centred around end-systole and end-diastole, respectively, with significant beat-to-beat variability. Afib leads to a larger beat-to-beat variability in both timing of occurrence and values of annulus size than in SR.
More Related Videos
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Dysrhythmias III: Characteristics of Dysrhythmias
Mitral Stenosis II: Clinical features and Diagnostic Tests
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Mitral Regurgitation I: Introduction
Mitral Stenosis I: Introduction