Related Experiment Video
Updated: Nov 12, 2025

Fluorescence Angiography for Evaluation of Aneurysm Perfusion and Parent Artery Patency in Rat and Rabbit Aneurysm Models
Published on: July 24, 2019
Intra-operative fluorescein videoangiography-related nephrotoxicity in intracranial aneurysm surgery: Single center,
Wojciech Świątnicki1, Filip Urbaniak1, Jarosław Szymański2
1Department of Neurosurgery, Maria Skłodowska-Curie Regional Specialist Hospital, District of Łódź-North, Zgierz, Poland.
Objectives:
Intra-operative fluorescein video angiography (FL-VA) has been given increasing attention recently and several studies reported its high utility in neurovascular surgery. The aim of this study was to evaluate the safety of FL-VA in a prospective, single-center cohort of patients operated due to cerebral aneurysms.
Patients And Methods:
This is an observational cohort study including 150 patients operated due to intracranial aneurysms. The study group consisted of 70 consecutive patients operated with the use of fluorescein video angiography. Post-operative acute kidney injury (AKI) occurrence as well as systemic adverse reactions were reported and further compared with 80 matched controls where FL-VA was not used. Statistical analysis was performed using non-parametric tests (Fisher's exact test).
Results:
Post-operative AKI was observed in 17,1% of patients in the study group with only half presenting with acute functional impairment. All of these patients presented initially due to aneurysm rupture. Pre-existing renal dysfunction and hypertension occurred in 16,7% and 33,3%, respectively. No systemic complications following FL-VA were reported. When compared to matched controls, no statistically significant difference regarding AKI occurrence was observed between these two patient populations.
Conclusion:
Intra-operative fluorescein video angiography proved to have a good safety profile in our cohort. The results of this study suggest that post-operative acute kidney injury observed in patients with subarachnoid hemorrhage is not related to fluorescein use.
Insights
Intra-operative fluorescein video angiography (FL-VA) is safe for cerebral aneurysm surgery. Post-operative kidney injury in patients with subarachnoid hemorrhage is not linked to FL-VA use.
Area of Science:
- Neurosurgery
- Vascular Surgery
- Medical Imaging
Background:
- Intra-operative fluorescein video angiography (FL-VA) is gaining traction in neurovascular surgery.
- Previous studies suggest high utility for FL-VA.
Purpose of the Study:
- To assess the safety of FL-VA in patients undergoing cerebral aneurysm surgery.
- To evaluate the incidence of post-operative acute kidney injury (AKI) and systemic adverse reactions associated with FL-VA.
Main Methods:
- Prospective, single-center observational cohort study.
- 150 patients with intracranial aneurysms were included.
- 70 patients received FL-VA, compared to 80 matched controls.
Main Results:
- No systemic complications were reported following FL-VA.
- Post-operative AKI occurred in 17.1% of the FL-VA group, with no statistically significant difference compared to controls.
- AKI in ruptured aneurysm patients was not definitively linked to fluorescein use.
Conclusions:
- Intra-operative FL-VA demonstrates a favorable safety profile in cerebral aneurysm surgery.
- The study suggests FL-VA is not a cause of post-operative AKI in patients with subarachnoid hemorrhage.
More Related Videos
04:01Indocyanine Green-Guided Intraoperative Imaging to Facilitate Video-Assisted Retroperitoneal Debridement for Treating Acute Necrotizing Pancreatitis
Published on: September 8, 2022
18:50Microsurgical Clip Obliteration of Middle Cerebral Aneurysm Using Intraoperative Flow Assessment
Published on: September 25, 2009
Related Concept Videos
Aneurysm IV: Nursing Management
Imaging Studies VII: Vascular Imaging
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Glaucoma: Overview
Angle Closure Glaucoma: Treatment