Related Experiment Video
Updated: Sep 13, 2026

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Determination of busulfan in human plasma by gas chromatography with electron-capture detection
T L Chen1, L B Grochow, L A Hurowitz
1John Hopkins Oncology Center, Johns Hopkins University, School of Medicine, Baltimore, MD 21205.
Abstract:
A simple and highly sensitive gas chromatographic method has been developed for the determination of busulfan in human plasma. After extraction of plasma specimens (clinical or spiked) with ethyl acetate, busulfan and the internal standard [1,8-bis(methanesulfonyloxy)octane] were derivatized with 2,3,5,6-tetrafluorothiophenol to yield compounds monitored by a 63Ni electron-capture detector. Sample recoveries from extraction and derivatization were greater than 78 and 91%, respectively. The limit of quantitation was 0.01 microgram/ml (0.04 microM) in 1 ml of plasma with a linear relationship over the 0.01-1.0 micrograms/ml (0.04-4 microM) concentration range. The method has been applied to analyze the plasma versus time profile of busulfan in human subjects following administration of an oral dose of 4 mg/kg per day as a marrow ablative chemotherapy for bone marrow transplantation.
More Related Videos
09:58Spatial Quantification of Drugs in Pulmonary Tuberculosis Lesions by Laser Capture Microdissection Liquid Chromatography Mass Spectrometry (LCM-LC/MS)
Published on: April 18, 2018
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II