Related Experiment Video
Updated: Aug 15, 2026

The Measurement and Treatment of Suppression in Amblyopia
Published on: December 14, 2012
Absence of overshoot in a dichotic masking condition
1Department of Psychology, University of Texas, Austin 78712.
Abstract:
Brief tonal signals presented soon after the onset of a masking noise are known to be less detectable than signals delayed by several hundred milliseconds. This difference in detectability is known as the "overshoot." Signals of two sorts were studied here--either interaurally in phase (S o) or interaurally out of phase by 180 degrees (S pi). When S omicron signals of 750 Hz and about 14 ms in duration were presented 4 ms after the onset of a diotic, broadband masking noise (N o), detectability was about 6 dB worse than when the signal was presented 325 ms after onset. By contrast, there was no such overshoot when S pi signals were presented at varying times after masker onset; detectability was about the same for all values of signal delay. Accordingly, the difference in performance between N o S o and N o S pi--the masking-level difference or MLD--was large (about 16 dB) with the shortest delays used and diminished (to about 9 dB) as the delay was increased. This absence of overshoot with the S pi signals is in accord with the well-established view that detectability in the dichotic masking conditions is based upon different stimulus information from that used in the diotic masking conditions. Specifically, the evidence confirms the common view that detectability in the diotic conditions is based more or less directly on neural firing rate, whereas, in the dichotic conditions, it is based upon interaural time differences encoded in the periodicity of neural firings.
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Facial Feedback Hypothesis

