[Dosimetric analysis of LINAC based stereotactic irradiation of brain tumours in CIRS SHANE phantom]
Dalma Mihály1, Barbara Melles-Bencsik1, Tamás Pócza1
1Sugárterápiás Központ, Országos Onkológiai Intézet, Budapest, Hungary. bela.dalma@yahoo.com.
Abstract:
The aim of the study was to compare the different stereotactic treatment plans and dose calculation algorithms for small targets with film dosimetry in anthropomorphic phantom. Treatment plans were prepared for multiple targets with single setup isocenter. Plans for three different irradiation techniques were generated using conformal arc with four non-coplanar arcs, RapidArc with two coplanar full arcs and RapidArc with four non-coplanar arcs in the Varian Eclipse v13.7.16 TPS. Conformal arc and RapidArc plans were calculated using AAA, Acuros XBDm and XBDw algorithms. Conformity index, gradient index and dose maximum were calculated for all PTVs. All measurements were made on the Varian TrueBeam linear accelerator. Comparison between computed and measured dose distributions was performed with gamma evaluation criteria of 3%, 3 mm; 3%, 1 mm and 2%, 2 mm. According to our results, the Eclipse AAA and AXB algorithms provide accurate dose distributions for homogeneous cranial irradiation.