Aerosol and Droplet Risk of Common Otolaryngology Clinic Procedures
Devi Sai Sri Kavya Boorgu1, Harish Dharmarajan2, Edward S Sim1
1University of Pittsburgh School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA.
Objectives:
Define aerosol and droplet risks associated with routine otolaryngology clinic procedures during the COVID-19 era.
Methods:
Clinical procedures were simulated in cadaveric heads whose oral and nasal cavities were coated with fluorescent tracer (vitamin B2) and breathing was manually simulated through retrograde intubation. A cascade impactor placed adjacent to the nares collected generated particles with aerodynamic diameters ≤14.1 µm. The 3D printed models and syringes were used to simulate middle and external ear suctioning as well as open suctioning, respectively. Provider's personal protective equipment (PPE) and procedural field contamination were also recorded for all trials using vitamin B2 fluorescent tracer.
Results:
The positive controls of nebulized vitamin B2 produced aerosol particles ≤3.30 µm and endonasal drilling of a 3D model generated particles ≤14.1 µm. As compared with positive controls, aerosols and small droplets with aerodynamic diameter ≤14.1 µm were not detected during rigid nasal endoscopy, flexible fiberoptic laryngoscopy, and rigid nasal suction of cadavers with simulated breathing. There was minimal to no field contamination in all 3 scenarios. Middle and external ear suctioning and open container suctioning did not result in any detectable droplet contamination. The clinic suction unit contained all fluorescent material without surrounding environmental contamination.
Conclusion:
While patients' coughing and sneezing may create a baseline risk for providers, this study demonstrates that nasal endoscopy, flexible laryngoscopy, and suctioning inherently do not pose an additional risk in terms of aerosol and small droplet generation. An overarching generalization cannot be made about endoscopy or suctioning being an aerosol generating procedure.
Level Of Evidence:
3.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...