Related Experiment Video
Updated: Nov 12, 2025

07:22
Arthroscopic Management of Massive Irreparable Rotator Cuff Tears: Whole Rotator Cable Reconstruction Using Proximal Biceps Tendon Autograft
Published on: June 6, 2025
309
Arthroscopic Single Lateral Row Repair Technique for Small Rotator Cuff Tears
Xunqi Cheow1, Denny Tjiauw Tjoen Lie1
1Department of Orthopaedic Surgery, Singapore General Hospital, Singapore.
Arthroscopy Techniques
|March 19, 2021
Summary
This study introduces a reproducible single lateral row technique for arthroscopic repair of small rotator cuff tears, improving tear approximation and reducing suture pullout for better surgical outcomes.
Area of Science:
- Orthopaedic Surgery
- Sports Medicine
- Arthroscopy
Background:
- Small symptomatic rotator cuff tears are prevalent in orthopaedic practice.
- Arthroscopic repair offers favorable outcomes for these injuries.
- Optimal arthroscopic repair techniques for small tears remain debated.
Purpose of the Study:
- To present a novel single lateral row technique for arthroscopic repair of small rotator cuff tears.
- To demonstrate the reproducibility and effectiveness of this technique.
- To improve tear approximation and minimize suture cutouts.
Main Methods:
- Arthroscopic surgical procedure utilizing a single lateral row fixation.
- Focus on achieving direct approximation of the torn rotator cuff.
- Technique designed to enhance suture retention within the bone.
Main Results:
- The presented technique allows for good approximation of the rotator cuff tear.
- The method effectively reduces the incidence of suture cutouts.
- The technique is considered reproducible and effective in clinical application.
Conclusions:
- A single lateral row technique provides a reproducible and effective method for arthroscopic repair of small rotator cuff tears.
- This approach facilitates superior tear approximation.
- The technique minimizes the risk of mechanical failure, such as suture cutouts.