Related Experiment Video
Updated: Nov 12, 2025

Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
Renogram image characteristics and the reproducibility of differential renal function measurement
Anita Brink1, Elena Libhaber2, Michael Levin3
1Division of Nuclear Medicine, Department of Paediatrics, University of Cape Town, Cape Town.
Purpose:
Patient factors such as age and glomerular filtration rate (GFR), have been implicated as causes for poor reproducibility of differential renal function (DRF) estimates on 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) renography. This study aims to investigate factors associated with the reproducibility of DRF measurements.
Methods:
The association between age, GFR and imaged derived image characteristics and reproducibility of repeated DRF estimates calculated using the area under the curve method and the Rutland Patlak method was analysed for cohort 1 (n = 127). The association between these variables and reproducibility of DRF was tested with univariate linear regression. The univariate linear regression results were used to plan the multiple linear regression combinations.The associations between variables identified and reproducibility of DRF values were then tested in a second cohort (n = 227).
Results:
The R2 values for goodness-to-fit for the multiple regression models ranged from 0.33 to 0.49 for cohort 1 and from 0.17 to 0.22 for cohort 2. Left kidney to background ratio (LKTBR) was significant in all the multiple linear regression combinations (P < 0.05). Right kidney to background ratio (RKTBR), right renal margins well defined, right renal margins poorly visualised, time visualisation right calyces and age were significant in most combinations. The reproducibility of DRF measurement was decreased when the kidney to background ratio (KTBR) was ≤2.
Conclusion:
Only LKTBR, RKTBR, right renal margins well defined, time visualisation right calyces and age predicted reproducibility for the measurement of DRF on 99mTc-MAG3 renograms. The KTBR should be incorporated into the renal processing software as a quality control step. The DRF values should be interpreted with caution if the KTBR is ≤2.0.
More Related Videos
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Imaging Studies II: Ultrasonography
Serum Studies: Renal Function Tests

