Water exchange-assisted versus carbon dioxide-insufflated single-balloon enteroscopy: a randomized controlled trial
Shaopeng Liu1, Tao Dong1, Yupeng Shi1
1State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi'an, China.
Background:
Single-balloon enteroscopy (SBE) is a valuable but difficult modality for the diagnosis and treatment of small-bowel disease. The water exchange method has the advantage of facilitating intubation during colonoscopy. Here, we evaluated the effects of water exchange on procedure-related variables related to SBE.
Methods:
This randomized controlled trial was conducted in a tertiary-care referral center in China. Patients due for attempted total enteroscopy were randomly allocated to undergo water exchange-assisted (water exchange group) or carbon dioxide-insufflated enteroscopy (CO2 group). All patients were planned to undergo both anterograde and retrograde procedures. The primary outcome was the total enteroscopy rate. Secondary outcomes included the maximal insertion depth, positive findings, procedural time, and adverse events.
Results:
In total, 110 patients were enrolled, with 55 in each group. Baseline characteristics between the two groups were comparable. Total enteroscopy was achieved in 58.2 % (32/55) of the water exchange group and 36.4 % (20/55) of the control group (P = 0.02). The mean (standard deviation) estimated intubation depth was 521.2 (101.4) cm in the water exchange group and 481.6 (95.2) cm in the CO2 group (P = 0.04). The insertion time was prolonged in the water exchange group compared with the CO2 group (178.9 [45.1] minutes vs. 154.2 [27.6] minutes; P < 0.001). Endoscopic findings and adverse events were comparable between the two groups.
Conclusions:
The water exchange method improved the total enteroscopy rate and increased the intubation depth during SBE. The use of water exchange did not increase the complications of enteroscopy.
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...