On the reduction of aperture complexity in kidney SABR
Mathieu Gaudreault1,2, Keith Offer1, Tomas Kron1,2
1Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.
Background:
Stereotactic ablative body radiotherapy (SABR) of primary kidney cancers is confounded by motion. There is a risk of interplay effect if the dose is delivered using volumetric modulated arc therapy (VMAT) and flattening filter-free (FFF) dose rates due to target and linac motion. This study aims to provide an efficient way to generate plans with minimal aperture complexity.
Methods:
In this retrospective study, 62 patients who received kidney SABR were reviewed. For each patient, two plans were created using internal target volume based motion management, on the average intensity projection of a four-dimensional CT. In the first plan, optimization was performed using a knowledge-based planning model based on delivered clinical plans in our institution. In the second plan, the optimization was repeated, with a maximum monitor unit (MU) objective applied in the optimization. Dose-volume, conformity, and complexity metric (with the field edge metric and the modulation complexity score) were compared between the two plans. Results are shown in terms of median (first quartile - third quartile).
Results:
Similar dosimetry was obtained with and without the utilization of an objective on the MU. However, complexity was reduced by using the objective on the MUs (modulation complexity score = 0.55 (0.50-0.61) / 0.33 (0.29-0.36), P-value < 10-10 , with/without the MU objective). Reduction of complexity was driven by a larger aperture area (area aperture variability = 0.68 (0.64-0.73) / 0.42 (0.37-0.45), P-value < 10-10 , with/without the MU objective). Using the objective on the MUs resulted in a more spherical dose distribution (sphericity 50% isodose = 0.73 (0.69-0.75) / 0.64 (0.60-0.68), P-value < 10-8 , with/without the MU objective) reducing dose to organs at risk given respiratory motion.
Conclusions:
Aperture complexity is reduced in kidney SABR by using an objective on the MU delivery with VMAT and FFF dose rate.
Related Concept Videos
Kidney Structure
Renal Corpuscle
Glomerulus: Structure and Function
The glomerulus is a tiny, intricate network of capillaries located at the beginning of the nephron. It's enveloped by the Bowman's capsule and receives its blood supply from an afferent arteriole, which divides into numerous...
External Anatomy of the Kidney
The kidneys are located in the retroperitoneal space on either side of the vertebral column, protected posteriorly by the 11th and 12th ribs. The right kidney sits slightly lower than the left owing to the presence of the liver...
Internal Anatomy of the Kidney
Anatomical Position and Dimensions
The kidneys are retroperitoneal organs positioned against the posterior abdominal wall on either side of the spine, roughly between the twelfth thoracic and third lumbar vertebrae. Each kidney is typically 10-12 cm long, 5-6 cm wide, and 3-4 cm thick, weighing about 150 grams.
Renal Cortex
The outermost region of the kidney is the...