Raman spectroscopic analysis of polysaccharides in popular Japanese rice cultivars
Giuseppe Pezzotti1, Wenliang Zhu2, Haruna Chikaguchi2
1Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, Kyoto 606-8585, Japan; Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo 160-0023, Japan; The Center for Advanced Medical Engineering and Informatics, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0854, Japan; Department of Immunology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, 465 Kajii-cho, Kyoto 602-8566, Japan.
Abstract:
Analytical algorithms based on Raman spectroscopy are proposed for the determination of amylopectin and amylose concentrations in polished white rice, and applied to characterize and compare linear and branched polysaccharide structures in nine different types of Japanese rice. A selected algorithm used symmetric bending vibrations of the COC glycosidic linkage from a relatively narrow spectral zone between 830 and 895 cm-1. It specifically compared the intensity of Raman signals from two types of bending common to both starch components (C1-O-C5 and C1-O-C4 at 868 and 855 cm-1, respectively) and that at the branch point peculiar to amylopectin (C1-O-C6 at 844 cm-1). Raman data were confronted with data collected by conventional amylose-iodine colorimetry method. Consistency was found between Raman and colorimetric methods over the entire series of tested rice cultivars, thus validating the newly proposed spectroscopic algorithm. The amylose content of the tested rice species broadly varied between 1.2 and 20.4%. The proposed Raman algorithm allows fast and nondestructive determination of amylose content in rice with minimal sample preparation. These characteristics might be key in the development of portable Raman devices capable to promptly screen polysaccharides in different rice cultivars with respect to their interannual and plantation-related fluctuations.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Biosynthesis of Polysaccharides
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...


