How to improve image quality of DWI of the prostate-enema or catheter preparation?
Carolin Reischauer1,2, Timmy Cancelli3, Sonaz Malekzadeh4,3
1Department of Medicine, University of Fribourg, Chemin du Musée 8, 1700, Fribourg, CH, Switzerland. carolin.reischauer@unifr.ch.
Objectives:
To compare the impact of laxative enema preparation versus air/gas suction through a small catheter on image quality of prostate DWI.
Methods:
In this single-center study, 200 consecutive patients (100 in each arm) with either enema or catheter preparation were retrospectively included. Two blinded readers independently assessed aspects of image quality on 5-point Likert scales. Scores were compared between groups and the influence of confounding factors evaluated using multivariable logistic regression. Prostate diameters were compared on DWI and T2-weighted imaging using intraclass correlation coefficients.
Results:
Image quality was significantly higher in the enema group regarding the severity of susceptibility-related artifacts (reader 1: 0.34 ± 0.77 vs. 1.73 ± 1.34, reader 2: 0.38 ± 0.86 vs. 1.76 ± 1.39), the differentiability of the anatomy (reader 1: 3.36 ± 1.05 vs. 2.08 ± 1.31, reader 2: 3.37 ± 1.05 vs. 2.09 ± 1.35), and the overall image quality (reader 1: 3.66 ± 0.77 vs. 2.26 ± 1.33, Reader 2: 3.59 ± 0.87 vs. 2.23 ± 1.38) with almost perfect inter-observer agreement (κ = 0.92-0.95). In the enema group, rectal distention was significantly lower and strongly correlated with the severity of artifacts (reader 1: ρ = 0.79, reader 2: ρ = 0.73). Furthermore, there were significantly fewer substantial image distortions, with odds ratios of 0.051 and 0.084 for the two readers which coincided with a higher agreement of the prostate diameters in the phase-encoding direction (0.96 vs. 0.89).
Conclusions:
Enema preparation is superior to catheter preparation and yields substantial improvements in image quality.
Key Points:
• Enema preparation is superior to decompression of the rectum using air/gas suction through a small catheter. • Enema preparation markedly improves the image quality of prostate DWI regarding the severity of susceptibility-related artifacts, the differentiability of the anatomy, and the overall image quality and considerably reduces substantial artifacts that may impair a reliable diagnosis.
Related Concept Videos
Imaging Studies II: Ultrasonography
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies VI: Voiding Cystourethrography and Cystography