Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Image quality, reading, and mammography service in four diagnostic imaging centers in Manizales, Colombia
Karol Julieth García1, Julián David Ocampo2, María Del Pilar Pardo3
1Centro de Innovación, Investigación, Desarrollo y Transferencia de Tecnología, Facultad de Ingeniería, Universidad de Caldas, Manizales, Colombia. karolgluna20@gmail.com.
Abstract:
Introduction: Mammography quality is directly related to the ability to detect an abnormality and, therefore, quality control is necessary for diagnostic imaging centers. Objective: To evaluate image quality, reading, and mammography service in some diagnostic imaging centers in Manizales, Colombia. Materials and methods: Four diagnostic imaging centers participated voluntarily in the study under confidentiality agreements. Out of 520 women attending the centers, 318 had a mammography. The infrastructure, technology, and human resources of each unit were evaluated based on visual inspections. A radiologist expert in reading and clinical interpretation of mammary images evaluated the quality of the image and the reading. We made the statistical analysis using anova, the kappa index, and the percentage of disagreement. Results: We found images of diminished quality mainly due to the presence of artifacts in 75 % of those evaluated, as well as non-compliance with identification criteria and image labeling. There were difficulties in taking the lateral median oblique projection given the absence of the inframammary. The level of agreement in the BI-RADS reporting was low in the four centers with important differences in the report and description of findings. Conclusion: The city’s diagnostic centers under evaluation are authorized for their operation. However, there are important deficiencies in image quality and reading, which highlights the need to seek quality standards starting from those aspects that can be improved upon.
More Related Videos
11:27A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...