Related Experiment Video
Updated: Nov 11, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Comparative optic and dosimetric characterization of the HYPERSCINT scintillation dosimetry research platform for
Emilie Jean1,2,3, François Therriault-Proulx4, Luc Beaulieu1,2
1Département de Physique, de génie Physique et d'optique et Centre de Recherche sur le Cancer, Université Laval, Quebec, QC, Canada.
Abstract:
This study introduces the HYPERSCINT research platform (HYPERSCINT-RP100, Medscint Inc., Quebec, Canada), the first commercially available scintillation dosimetry platform capable of multi-point dosimetry through the hyperspectral approach. Optic and dosimetric performances of the system were investigated through comparison with another commercially available solution, the Ocean Optics QE65Pro spectrometer. The optical characterization was accomplished by measuring the linearity of the signal as a function of integration time, photon detection efficiency and spectral resolution for both systems under the same conditions. Dosimetric performances were then evaluated with a 3-point plastic scintillator detector (mPSD) in terms of signal to noise ratio (SNR) and signal to background ratio (SBR) associated with each scintillator. The latter were subsequently compared with those found in the literature for the Exradin W1, a single-point plastic scintillator detector. Finally, various beam measurements were realized with the HYPERSCINT platform to evaluate its ability to perform clinical photon beam dosimetry. Both systems were found to be comparable in terms of linearity of the signal as a function of the intensity. Although the QE65Pro possesses a higher spectral resolution, the detection efficiency of the HYPERSCINT is up to 1000 time greater. Dosimetric measurements shows that the latter also offers a better SNR and SBR, surpassing even the SNR of the Exradin W1 single-point PSD. While doses ranging from 1 to 600 cGy were accurately measured within 2.1% of the predicted dose using the HYPERSCINT platform coupled to the mPSD, the Ocean optics spectrometer shows discrepancies up to 86% under 50cGy. Similarly, depth dose, full width at half maximum region of the beam profile and output factors were all accurately measured within 2.3% of the predicted dose using the HYPERSCINT platform and exhibit an average difference of 0.5%, 1.6% and 0.6%, respectively.
More Related Videos
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017