Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Comparison of Self-Expanding RDV Perceval S versus TAVI ACURATE neo/TF
Stephen Gerfer1, Victor Mauri2, Elmar Kuhn1
1Department of Cardiothoracic Surgery, Heart Center, University Hospital of Cologne, Cologne, Germany.
Background:
Rapid deployment aortic valve replacement (RDAVR) and transcatheter aortic valve implantation (TAVI) have emerged as increasingly used alternatives to conventional aortic valve replacement to treat patients at higher surgical risk. Therefore, in this single-center study, we retrospectively compared clinical outcomes and hemodynamic performance of two self-expanding biological prostheses, the sutureless and rapid deployment valve (RDV) Perceval-S (PER) and the transcatheter heart valve (THV) ACURATE neo/TF (NEO) in a 1:1 propensity-score-matching (PSM) patient cohort.
Methods:
A total of 332 consecutive patients with symptomatic aortic valve stenosis underwent either singular RDAVR with PER (119) or TAVI with NEO (213) at our institutions between 2012 and 2017. To compare the unequal patient groups, a 1:1 PSM for preoperative data and comorbidities was conducted. Afterward, 59 patient pairs were compared with regard to relevant hemodynamic parameter, relevant paravalvular leak (PVL), permanent postoperative pacemaker (PPM) implantation rate, and clinical postoperative outcomes.
Results:
Postoperative clinical short-term outcomes presented with slightly higher rates for 30-day all-cause mortality (PER = 5.1% vs. NEO = 1.7%, p = 0.619) and major adverse cardiocerebral event in PER due to cerebrovascular events (transient ischemic attack [TIA]-PER = 3.4% vs. TIA-NEO = 1.7%, p = 0.496 and Stroke-PER = 1.7% vs. Stroke-NEO = 0.0%, p = 1). Moreover, we show comparable PPM rates (PER = 10.2% vs. NEO = 8.5%, p = 0.752). However, higher numbers of PVL (mild-PER = 0.0% vs. NEO = 55.9%, p = 0.001; moderate or higher-PER = 0.0% vs. NEO = 6.8%, p = 0.119) after TAVI with NEO were observed.
Conclusion:
Both self-expanding bioprostheses, the RDV-PER and THV-NEO provide a feasible option in elderly and patients with elevated perioperative risk. However, the discussed PER collective showed more postoperative short-term complications with regard to 30-day all-cause mortality and cerebrovascular events, whereas the NEO showed higher rates of PVL.
More Related Videos
13:00Measuring Attention and Visual Processing Speed by Model-based Analysis of Temporal-order Judgments
Published on: January 23, 2017
09:33Neuronavigated Focalized Transcranial Direct Current Stimulation Administered During Functional Magnetic Resonance Imaging
Published on: November 15, 2024
Related Concept Videos
Comparing Experimental Results: Student's t-Test
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Improving Translational Accuracy
Improving Translational Accuracy
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...