Related Experiment Video
Updated: Aug 13, 2026

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Case Report: 18F-FDG PET-CT for Diagnosing Prosthetic Device-Related Infection in an Infant With CHD
Junpei Kawamura1, Kentaro Ueno1, Eri Taimura1
1Department of Pediatrics, Kagoshima University, Kagoshima, Japan.
Abstract:
Patients who have undergone cardiac surgery using prosthetic devices have an increased risk of developing prosthetic device-related infection and mediastinitis. However, accurate diagnosis of prosthetic device-related infection can be difficult to evaluate and treat with antibiotic therapy alone. In recent years, 18F-fluorodeoxyglucose positron emission tomography-computed tomography (18F-FDG PET-CT) has made promising contributions to detect infective endocarditis, pacemaker infections, or other inflammations. Nevertheless, 18F-FDG PET-CT for congenital heart disease (CHD) with device infection has been sparsely reported. We present an infantile girl diagnosed with pulmonary atresia with a ventricular septal defect who underwent replacement of the right ventricle-to-pulmonary artery (RV-PA) conduit for improvement cyanosis. She developed high fever and was diagnosed with mediastinitis and bacteremia by Pseudomonas aeruginosa (P. aeruginosa) on postoperative day 4. Mediastinal drainage and 6 weeks of antibiotic therapy improved her condition, but bacteremia flared up on postoperative day 56. Despite a long course of antibiotic therapy, she had two more recurrences of bacteremia with the detection of P. aeruginosa. Echocardiography and chest contrast CT showed no evidence of vegetation and mediastinitis. On postoperative day 115, 18F-FDG PET-CT revealed an accumulation on the RV-PA conduit (SUV max 3.4). Finally, she developed an infectious ventricular pseudo-aneurysm on postoperative day 129 and underwent aneurysm removal and RV-PA conduit replacement on postoperative day 136. Our case showed the importance of 18F-FDG PET-CT for diagnosing specific localization of prosthetic device-related infection which is hard to detect using other imaging techniques. It can be a useful diagnostic tool for infantile patients with CHD with cardiac prosthetic devices and improve subsequent clinical treatments.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT