Related Experiment Video
Updated: Nov 11, 2025

Application of Straight-needle, Three-tailed, Knot-free, Peritoneal Sutures in Laparoscopic Transabdominal Preperitoneal Hernia Repair
Published on: November 12, 2021
Anterior approach levator plication for congenital ptosis, absorpable versus non absorpable sutures
Moustafa Salamah1, Ashraf Mahrous Eid2, Hani Albialy2
1Faculty of Human Medicine, Zagazig University, Zagazig, Egypt.
Purpose:
To compare the efficacy of two different suture types in levator plication for correction of congenital ptosis.
Subjects And Methods:
Prospective comparative interventional randomized study involving 42 eyes of 42 patients aged more than 6 years with congenital ptosis and good levator action. The exclusion criteria were as follows: bilateral ptosis, history of previous surgery, fair or poor levator action, and associated other ocular diseases. Patients were randomized into group A, in which double-armed 5/0 polyester Ethibond were used, and group B, in which double-armed 5/0 Coated Vicryl® (polyglactin 910) suture material we used. Outcomes including eyelid height and stability of eyelid height over time were compared with follow-up data. The MRD was 4.05 ± 0.36 mm and 3.95 ± 0.34 after 1 week for both groups A and B, respectively. At the end of study follow up period (24 weeks), the MRD was 3.60 ± 0.42 mm in group A, and 2.52 ± 0.85 mm in group B.
Conclusion:
No difference in eyelid height between two groups in early postoperative period, but the postoperative eyelid height was more stable over time in the 5/0 polyester Ethibond group (group A) than in the 5/0 Coated Vicryl® (polyglactin 910) group (group B).
More Related Videos
03:24Author Spotlight: Development and Application of a Novel Suture Technique for Annular Fibrosus Repair in Percutaneous Transforaminal Endoscopic Discectomy
Published on: January 26, 2024
03:43Laparoscopic Non-Mesh Cerclage Pectopexy for Pelvic Organ Prolapse
Published on: September 13, 2022