Fault detection and isolation of gas turbine using series-parallel NARX model
Saeed Amirkhani1, Amirreza Tootchi1, Ali Chaibakhsh1
1Faculty of Mechanical Engineering, University of Guilan, Rasht, Guilan 41996-13776, Iran; Intelligent System and Advanced Control Lab, University of Guilan, Rasht, Guilan 41996-13776, Iran.
Abstract:
This paper describes the design and implementation of intelligent dynamic models for fault detection and isolation of V94.2(5)/MGT-70(2) single-axis heavy-duty gas turbine system. The series-parallel structure of nonlinear autoregressive exogenous (NARX) models are used for fault detection, which initiate greater robustness and stability against uncertainties and perturbations. Moreover, to improve the fault detection robustness against uncertainties, the Monte Carlo technique is used in the proposed fault detection structure to select the best threshold. The analysis of fault detectability and fault detection sensitivity are accomplished to analyze the performance of the suggested technique. The fault isolation process is also achieved by using the residual classification approach. The results show the feasibly, robustness, and performance of the presented approach for fault diagnosis of nonlinear systems in the presence of uncertainties.
Related Concept Videos
Power System Three-Phase Short Circuits
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...