Updates in Hemodynamic Monitoring: A Review for Pharmacists
Chelsea N Lopez1, Elisabeth M Sulaica2, Kevin R Donahue1
1Department of Pharmacy, Houston Methodist Hospital, Houston, TX, USA.
Abstract:
Vital signs are regularly monitored in hospitalized patients. In the intensive care unit (ICU), traditional non-invasive blood pressure monitoring and telemetry may not provide enough information to determine the etiology of hemodynamic instability or guide intervention. Arterial catheters remain the gold-standard for continuous blood pressure monitoring and are commonly used in ICU patients. Pulmonary artery catheters and central venous catheters are beneficial in select patient populations and provide more advanced and specific information about a patient's hemodynamics. However, neither are benign and can increase risk of complications such as infection, arrhythmias, pneumothorax and vascular or valvular damage. In the past 10 years, the development of reliable non-invasive (NICOM), or minimally-invasive (MICOM), cardiac output monitoring devices has accelerated. The MICOM devices require an arterial catheter to obtain hemodynamic values, whereas NICOM devices do not require any arterial or venous access. These devices have emerged to be particularly useful in evaluating and managing patients with suspected mixed shock. As these devices become more prevalent, it is imperative that clinical pharmacists become familiar with interpreting this data as it may have a substantial impact on medication selection and optimization. This review will discuss the basics of NICOM and MICOM devices, limitations with these methods of monitoring, and clinical application for pharmacists.
Related Concept Videos
Therapeutic Drug Monitoring: Overview and Classification
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.