Optical Hemodynamic Imaging of Jugular Venous Dynamics During Altered Central Venous Pressure
Objective:
An optical imaging system is proposed for quantitatively assessing jugular venous response to altered central venous pressure.
Methods:
The proposed system assesses sub-surface optical absorption changes from jugular venous waveforms with a spatial calibration procedure to normalize incident tissue illumination. Widefield frames of the right lateral neck were captured and calibrated using a novel flexible surface calibration method. A hemodynamic optical model was derived to quantify jugular venous optical attenuation (JVA) signals, and generate a spatial jugular venous pulsatility map. JVA was assessed in three cardiovascular protocols that altered central venous pressure: acute central hypovolemia (lower body negative pressure), venous congestion (head-down tilt), and impaired cardiac filling (Valsalva maneuver).
Results:
JVA waveforms exhibited biphasic wave properties consistent with jugular venous pulse dynamics when time-aligned with an electrocardiogram. JVA correlated strongly (median, interquartile range) with invasive central venous pressure during graded central hypovolemia (r = 0.85, [0.72, 0.95]), graded venous congestion (r = 0.94, [0.84, 0.99]), and impaired cardiac filling (r = 0.94, [0.85, 0.99]). Reduced JVA during graded acute hypovolemia was strongly correlated with reductions in stroke volume (SV) (r = 0.85, [0.76, 0.92]) from baseline (SV: 79 ± 15 mL, JVA: 0.56 ± 0.10 a.u.) to -40 mmHg suction (SV: 59 ± 18 mL, JVA: 0.47 ± 0.05 a.u.; p 0.01).
Conclusion:
The proposed non-contact optical imaging system demonstrated jugular venous dynamics consistent with invasive central venous monitoring during three protocols that altered central venous pressure.
Significance:
This system provides non-invasive monitoring of pressure-induced jugular venous dynamics in clinically relevant conditions where catheterization is traditionally required, enabling monitoring in non-surgical environments.
Related Concept Videos
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Imaging Studies VII: Vascular Imaging
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System IV: CMRI