Related Experiment Video
Updated: Nov 11, 2025

Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
Ground-truth-free deep learning for artefacts reduction in 2D radial cardiac cine MRI using a synthetically generated
D Chen1, T Schaeffter1,2,3, C Kolbitsch1,2
1Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin, Germany.
Abstract:
In this work, we consider the task of image reconstruction in 2D radial cardiac cine MRI using deep learning (DL)-based regularization. As the regularization is achieved by employing an image-prior predicted by a pre-trained convolutional neural network (CNN), the quality of the image-prior is of essential importance. The achievable performance of any DL-based method is limited by the amount and the quality of the available training data. For fast dynamic processes, obtaining good-quality MR data is challenging because of technical and physiological reasons. In this work, we try to overcome these problems by a transfer-learning approach which is motivated by a previously presented DL-method (XT,YT U-Net). There, instead of training the network on the whole 2D dynamic images, it is trained on 2D spatio-temporal profiles (xt,yt-slices) which show the temporal changes of the imaged object. Therefore, for the training and test data, it is more important that their spatio-temporal profiles share similar local features rather than being images of the same anatomy. This allows us to equip arbitrary data with simulated motion that resembles the cardiac motion and use it as training data. By doing so, it is possible to train a CNN which is applicable to cardiac cine MR data without using ground-truth cine MR images for training. We demonstrate that combining XT,YT U-Net with the proposed transfer-learning strategy delivers comparable performance to CNNs trained on cardiac cine MR images and in some cases even qualitatively surpasses these. Additionally, the transfer-learning strategy was investigated for a 2D and 3D U-Net. The images processed by the the CNNs were used as image-priors in the CNN-regularized iterative reconstruction. The XT,YT U-Net yielded visibly better results than the 2D U-Net and slightly better results than the 3D U-Net when used in combination with the presented transfer learning-strategy.
More Related Videos
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021