Assessment of Bone Fracture Healing Using Micro-Computed Tomography
Published on: December 9, 2022
Comparison of bone single-photon emission computed tomography (SPECT)/CT and bone scintigraphy in assessing knee
Young-Sil An1, Do Young Park2, Byoung-Hyun Min2
1Department of Nuclear Medicine and Molecular Imaging, School of Medicine, Ajou University, 206, World cup-ro, Yeongtong-gu, Suwon-si, Suwon, Gyeonggi-do, 16499, Korea. aysays77@naver.com.
Background:
This study attempted to compare the radiopharmaceutical uptake findings of planar bone scintigraphy (BS) and single photon emission computed tomography (SPECT)/computed tomography (CT) performed on knee joints.
Methods:
We retrospectively included 104 patients who underwent bone SPECT/CT and BS 4 h after the intravenous administration of technetium-99m-hydroxymethylene diphosphonate (99mTc-HDP) for pain in the knee joint. The uptake degree of each of the knee regions (medial femoral, lateral femoral, medial tibial, lateral tibial, and patellar area) in planar images and SPECT/CT were evaluated by visual (grades 0 to 2) and quantitative analyses (uptake counts for planar image and standardized uptake values [SUVs] for SPECT/CT).
Results:
The uptake grades assessed visually on the planar images differed significantly from the uptake grades on SPECT/CT images in all areas of the knee (all p < 0.001), and SPECT/CT imaging revealed a larger number of uptake lesions than those noted in planar imaging for each patient (3.3 ± 2.0 vs 2.4 ± 2.3, p < 0.0001). In all regions of the knee, all of the quantitative values, including uptake counts obtained from the planar image as well as the maximum SUV (SUVmax) and mean SUV (SUVmean) obtained from SPECT/CT, showed statistically higher values as their visual grades increased (all p < 0.001). However, when analyzed for each area, only the SUVmax showed a significant difference by grade in all knee regions. Quantitative uptake values obtained from planar images were moderately correlated with SUVs of SPECT/CT images (r = 0.58 for SUVmean and r = 0.53 for SUVmax, all p < 0.001) in the total knee regions. Looking at each area, there was a significant but low correlation between the uptake counts of the planar images and the SUVs on SPECT/CT in the right lateral tibial region (r = 0.45 for SUVmean, r = 0.31 for SUVmax, all p < 0.001).
Conclusions:
In assessing knee joints, the findings of planar images and SPECT/CT images differ both visually and quantitatively, and more lesions can be found in SPECT/CT than in the planar images. The SUVmax could be a reliable value to evaluate knee joint uptake activity.
More Related Videos
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System V: CT