Related Experiment Video
Updated: Nov 11, 2025

Dried Blood Spots - Preparing and Processing for Use in Immunoassays and in Molecular Techniques
Published on: March 13, 2015
Prevalence of Detectable Biotin in Five US Emergency Department Patient Cohorts
Ian L Gunsolus1, Matthew Matias2, John Prostko2
1Department of Pathology, Medical College of Wisconsin, Milwaukee, WI, USA.
Background:
The objective of this study was to estimate the prevalence of biotin supplementation in United States emergency department patients using a multi-site, geographically distributed sampling model.
Methods:
Biotin was measured using an Abbott ARCHITECT Biotin research use only assay in 7118 emergency department patient serum or plasma samples from five US medical centers. Samples with biotin ≥10 ng/mL underwent additional LC-MS/MS confirmatory testing for biotin and its primary metabolites. The overall and site-specific prevalence of detectable biotin was determined using the screening assay while biotin speciation (i.e., prevalence of detectable metabolites) was determined using LC-MS/MS.
Results:
Of 7118 samples screened, 291 (4.1%) had biotin ≥10 ng/mL and were considered positive. Across five medical centers, the fraction of positive samples ranged from 2.0% to 5.4%. The maximum biotin concentration observed was 355 ng/mL. Of the 285 positive screens that underwent additional LC-MS/MS testing, 89 (31%) showed detectable biotin, bisnorbiotin, and/or biotin sulfoxide. Biotin, bisnorbiotin, and biotinsulfoxide were detected in 82/89 (92.1%), 61/89 (68.5%), and 18/89 (20.2%) samples, respectively; biotin was detected in the absence of either metabolite in 18/89 (20.2%) samples.
Conclusions:
Using a screening assay, 4.1% of emergency department patient samples were found to be potentially susceptible to interference from biotin. Confirmatory testing showed detectable biotin and/or biotin metabolites in 31% of positive screens (1.3% overall). The prevalence of biotin ≥10 ng/mL varied 2-3-fold across US emergency department patient cohorts. Biotin metabolites were observed in 80% of samples confirmed to have detectable biotin species by LC-MS/MS, suggesting that rigorous assessments of assay susceptibility to biotin interference, often performed using in vitro studies, should consider the potential role of biotin metabolites present in vivo.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...