Microporous P-doped carbon spheres sensory electrode for voltammetry and amperometry adrenaline screening in human
Mohammed Y Emran1,2, Mohamed A Shenashen1, Sherif A El-Safty3
1Research Center for Functional Materials, National Institute for Materials Science (NIMS), 1-2-1 Sengen, Tsukuba-shi, Ibaraki-ken, 305-0047, Japan.
Abstract:
An electrochemical sensor-based phosphorus-doped microporous carbon spheroidal structures (P-MCSs) has been designed for selective adrenaline (ADR) signaling in human blood serum. The P-MCS electrode sensor is built with heterogeneous surface alignments including multiple porous sizes with open holes and meso-/macro-grooves, rough surface curvatures, and integral morphology with interconnected and conjugated microspheres. In addition, the P atom-doped graphitic carbon forms highly active centers, increases charge mobility on the electrode surface, creates abundant active centers with facile functionalization, and induces binding to ADR molecules. The designed P-MCS electrode exhibits ultrasensitive monitoring of ADR with a low detection limit of 0.002 μM and high sensitivity of 4330 μA μM-1 cm-2. In addition, two electrochemical techniques, namely, square wave voltammetry (SWV) and chronoamperometry (CA), were used; these techniques achieve high stability, fast response, and a wide linear range from 0.01 to 6 μM. The sensing assays based on P-MCSs provide evidence of the formation of active interfacial surface-to-ADR binding sites, high electron diffusion, and heavy target loads along with/without a plane of spheroids. Thus, P-MCSs can be used for the routine monitoring of ADR in human blood serum, providing a fast response, and requiring highly economical materials at extremely low concentrations. Electrode surface modulation based on P-doped carbon spheres (P-MCS) exhibits high electrochemical activity with fast charge transport, multi-diffusible active centers, high loading of ADR, and facile molecular/electron diffusion at its surface. The P-MCS sensitively and selectively detects the ADR in human fluids and can be used for clinical investigation of some neuronal diseases such as Alzheimer diseases.
More Related Videos
08:19Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Amperometry: Overview
Potentiometry: Membrane Electrodes
High-Performance Liquid Chromatography: Types of Detectors