Accuracy of a single-lead mobile smartphone electrocardiogram for QT interval measurement in patients undergoing
Erika N Titus-Lay1,2, Heather A Jaynes2, Elena Tomaselli Muensterman2
1Department of Pharmacy Services, Eskenazi Health, Indianapolis, Indiana, USA.
Study Objective:
Methadone is associated with QT interval prolongation and torsades de pointes. Expert panel recommendations advocate a pre-methadone electrocardiogram (ECG) and another ECG at 30 days of therapy in patients with risk factors. Some guidelines recommend a pre-methadone ECG and routine ECG monitoring in all methadone patients, but this is controversial due to the resources required. Availability of a convenient, less resource-intensive method of ECG monitoring for patients taking methadone is desirable. The objective of this study was to assess the accuracy of a handheld smartphone ECG (iECG) for QT measurement in patients on maintenance methadone therapy in an urban opioid treatment program.
Design:
Prospective study.
Setting:
Urban opioid treatment program.
Patients:
n = 115 patients in normal sinus rhythm who were on steady-state maintenance methadone therapy INTERVENTION: Patients (n = 115) underwent a simultaneous 12-lead ECG and a single-lead iECG.
Measurements And Main Results:
The first three QT and RR intervals from lead II of the 12-lead ECG and simulated lead I from the iECG were compared using the Bland-Altman analysis of measurement agreement. Mean [± standard deviation) age was 34 ± 11 years; 71% were female, 75% were white. Compared to the 12-lead ECG, the iECG was associated with a QTc bias of - 0.14 ms (SD = 12 ms, 95% CI = -2.4 to 2.1 ms). The absolute mean difference in QTc between the two methods was 9.5 ± 7.1 ms. For identification of patients with methadone-associated QTc prolongation, the iECG performed moderately well [c-statistic 0.97 (95% CI 0.91-0.99); sensitivity and specificity 75% (95% CI 43-95%) and 99% (95% CI 94-99%), respectively]. The positive and negative likelihood ratios of the iECG for identifying patients with methadone-associated QTc prolongation were 77.25 (95% CI 10.69 to 558.18) and 0.25 (95% CI 0.09 to 0.67), respectively, while the positive and negative predictive values were 90% (95% CI 56-99%) and 97% (95% CI 92-99%), respectively. The accuracy of the iECG for identifying patients with QTc prolongation was 97% (95% CI 91-99%).
Conclusion:
A handheld smartphone ECG is accurate for QT interval measurement in patients taking maintenance methadone therapy, and its performance is moderately good for identifying patients with methadone-associated QTc prolongation.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....