Related Experiment Video
Updated: Nov 11, 2025

A Zebrafish Embryo Model for In Vivo Visualization and Intravital Analysis of Biomaterial-associated Staphylococcus aureus Infection
Published on: January 7, 2019
Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a
Sara Pichtchoulin1, Ingrid Selmeryd2, Elisabeth Freyhult3
1Department of Clinical Physiology, Västmanland County Hospital, Västerås, Sweden.
Background:
Due to a high incidence of cardiac implantable electronic device-associated infective endocarditis (CIED-IE) in cases of Staphylococcus aureus bacteremia (SAB) and high mortality with conservative management, guidelines advocate device removal in all subjects with SAB. We aimed to investigate the clinical course of SAB in patients with a CIED (SAB+CIED) in a Swedish county hospital setting and relate it to guideline recommendations.
Methods:
All CIED carriers with SAB, excluding clinical pocket infections, in the County of Västmanland during 2010-2017 were reviewed retrospectively.
Results:
There were 61 cases of SAB+CIED during the study period, and CIED-IE was diagnosed in 13/61 (21%) cases. In-hospital death occurred in 19/61 (31%) cases, 34/61 (56%) cases were discharged with CIED device retained, and 8/61 (13%) cases were discharged after device removal. Subjects dying during hospitalization were elderly and diseased. No events was seen if the CIED was removed. Among four discharged cases with conservatively managed CIED-IE one relapse occured. Among 30 cases discharged with retained CIED and no evidence of IE, 22/30 (73%) cases had an uneventful follow-up, whereas adverse events secondary to overlooked CIED-IE were likely in 1/30 (3%) cases and could not be definitely excluded in additionally 4/30 (13%) cases.
Conclusions:
During the study period, management became more active and prognosis improved. The heterogeneity within the population of SAB+CIED suggests that a management strategy based on an individual risk/benefit analysis could be an alternative to mandatory device removal.
Related Concept Videos
Endocarditis I: Introduction
Endocarditis III: Medical Management
Endocarditis II: Clinical Features of Infective Endocarditis
Bacterial Signaling
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.

