Related Experiment Video
Updated: Nov 11, 2025

Author Spotlight: A Novel Protocol for Intracameral Injections to Enhance Precision in Rodent Ophthalmology
Published on: May 31, 2024
25-Gauge Catheter as a Surrogate to Anterior Chamber Maintainer in Trabeculectomy
Alessandra A Kusabara1, Niro Kasahara1,2
167742Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, Brazil.
Abstract:
A flat anterior chamber (AC) is a distinctive feature in status post vitrectomy eyes during trabeculectomy. The use of AC maintainers is useful to help prevent this peroperative situation. We herein describe the surgical technique using a 25-gauge intravenous catheter as a surrogate to conventional AC maintainers. A potential advantage of this approach is the low cost in the current economic environment with limited health restraints.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Hemodialysis I: Introduction