Related Experiment Video
Updated: Jul 27, 2026

A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
Preventing cerebral spinal fluid leakage following endoscopy through a burr hole using a novel watertight closure:
Patrick Graupman1, Eric S Nussbaum2, Puja D Patel3
1Department of Neurosurgery, Gillette Children's Hospital, St. Paul, MN, USA.
Background:
Cerebrospinal fluid (CSF) leakage is a common complication after neuroendoscopic surgery through a burr hole and can lead to further complications including infection.
Methods:
We describe the use of a dural substitute larger than the burr hole itself, placed over the burr hole and then secured underneath a burr hole cover by microscrews running through the graft itself into the underlying skull.
Results:
This simple technical modification contributes to achieving a watertight seal to aid in preventing CSF leakage in this setting.
Conclusions:
Our technical modification of endoscopy through a burr hole may help to prevent postoperative CSF leak and secondary CSF infections.