A down-to-earth analyst view of rotational ambiguity in second-order calibration with multivariate curve resolution -
1Departamento de Química Analítica, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Instituto de Química Rosario (CONICET-UNR), Suipacha 531 (2000), Rosario, Argentina.
Abstract:
Rotational ambiguity is a phenomenon with the potential of generating an uncertainty in the estimation of analyte concentrations in protocols based on matrix instrumental data processed by multivariate curve resolution - alternating least-squares (MCR-ALS). This is particularly relevant when the second-order advantage is to be achieved, i.e., when selected analytes are determined in unknown samples having unexpected constituents, not considered in the calibration set of samples. It is therefore imperative that analytical chemists developing second-order multivariate calibration methods using MCR-ALS acknowledge the relevance of this issue, and more importantly, have access to the required tools to size the relative impact of this potential source of uncertainty on the estimated analyte concentrations. The purpose of this tutorial is to provide a down-to-earth view of rotational ambiguity, by studying in detail a synthetic example mimicking a typical chromatographic-spectral experiment, where a set of calibration samples is joined with an unknown sample having an uncalibrated interference. After explaining the background information needed to understand the origin of the phenomenon, the available tools for the estimation of the feasible MCR-ALS solutions and the derived uncertainty on analyte predictions will be discussed. A multi-component experimental system will also be discussed, stressing the fact that rotational ambiguity uncertainties, however small, should always be estimated and reported.
More Related Videos
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
07:03Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Published on: February 23, 2017
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Curvilinear Motion: Normal and Tangential Components
The positive direction of the t-axis aligns with the increasing position of the car along the curved path, denoted by the unit vector ut. Simultaneously, the n-axis, perpendicular to the t-axis, dissects the curved path into differential arc segments, each forming the arc of a circle with a radius of...
Curvilinear Motion: Polar Coordinates
The particle's location is described using a unit vector along the radial direction. Deriving the particle's position...