Biomechanical analysis of practitioner's gesture for peripheral venous catheter insertion
K Torossian1, M Ottenio2, A-C Brulez3
1Laboratoire de Tribologie et Dynamique des Systèmes, UMR CNRS 5513, Ecole Centrale de Lyon, 36 avenue Guy de Collongues, 69134 Ecully, France; Univ Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, IFSTTAR, LBMC UMR_T9406, F69622 Lyon, France.
Abstract:
Peripheral venous catheter insertion (PVCI) is one of the most common procedures performed by healthcare professionals but remains technically difficult. To develop new medical simulators with better representativeness of the human forearm, an experimental study was performed to collect data related to the puncturing of human skin and a vein in the antebrachial area. A total of 31 volunteers participated in this study. Force sensors and digital image correlation were used to measure the force during the palpation and puncturing of the vein and to retrieve the kinematics of the practitioner's gesture. The in vivo skin rupture load, vein rupture load, and friction loads for skin only and for both the skin and vein were (mean ± standard deviation) 0.85 ± 0.34 N, 1.25 ± 0.37 N, -0.49 ± 0.19 N, and -0.51 ± 0.16 N, respectively. The results of this study can be used to develop realistic skin and vein substitutes and mechanically assess them by reproducing the practitioner's gesture in a controlled fashion.
More Related Videos
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
07:29Author Spotlight: Development of a Standardized Acupuncture Tool Inspired by Advanced Techniques for Improved Safety and Precision
Published on: January 10, 2025
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: