Is infrared thermometry suitable for the determination of the time since death based on ear temperature? A
Kenza Laplace1, Eric Baccino2, Pierre-Antoine Peyron2
1Department of Forensic Medicine, University Hospital of Montpellier, Montpellier, France. k-laplace@chu-montpellier.fr.
Abstract:
Infrared thermometry has been proposed as an interesting alternative to probe thermometers for recording ear temperature in cadavers to estimate the postmortem interval (PMI), but it has still to be validated in this setting. Our objective was to compare the performance of an infrared thermometer to that of a reference probe thermometer for measuring ear temperature. Temperature measurements were performed on 100 cadavers (mean PMI: 4.5 ± 2.5 h) using the infrared and the probe thermometers. The repeatability of the measurements, their correlation, and the agreement between both methods were evaluated. We showed a good repeatability of the measurements with the infrared thermometer (Lin's concordance correlation coefficient (CCC) = 0.93 [0.72;0.98] for the right ear; CCC = 0.94 [0.75;0.98] for the left ear), and there was a strong and significant correlation between measurements provided by the two instruments (p < 0.001). However, a poor agreement was found between both methods, with a systematic underestimation of about 2 °C of the ear temperature when measured with the infrared thermometer. Data from auricular infrared thermometry should not be applied to algorithms developed for probe thermometers to estimate the PMI. Further research is needed to develop a reliable algorithm specifically based on infrared thermometry.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...


