Related Experiment Video
Updated: Nov 11, 2025

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
A new technique that prevents paravalvular leakage after aortic valve replacement using a rapid-deployment valve
Taira Yamamoto1, Daisuke Endo1, Hironobu Yamaoka2
1Department of Cardiovascular Surgery, Juntendo University, Tokyo, Japan.
Background:
We report our 1-year single-center experience of a new technique of aortic valve replacement using a rapid-deployment valve (RD-AVR) to avoid postoperative complications. We also report the unexpected pitfalls and handling techniques that we have seen in past cases.
Methods:
We performed aortic valve replacement on 38 patients between May 2019 and April 2020. Their mean age was 74 years. The primary outcomes were in-hospital mortality and short-term results during a 1-year follow-up period, while the secondary outcomes were related to prosthetic valve function, especially paravalvular leakage (PVL). We further analyzed the relationship between the new technique and its outcomes.
Results:
The mean operative time was 196 min. There were no in-hospital deaths, and the mean duration of postoperative hospital stay was 11.8 days. Valvular measurements using three-dimensional computed tomography were larger and more accurate than those measured using ultrasonic echocardiography. Postoperative RD-AVR prosthetic valve function was excellent. However, PVL occurred in four cases 1 week and 1 year postoperatively and regurgitation did not improve. A gap associated with PVL was identified below the right-noncoronary commissure. To prevent PVL, we additionally stitched this gap in the later 18 cases; there was no case of PVL and no new pacemaker implantation in these cases.
Conclusions:
PVL is more likely to occur if there is a gap below the R-N commissure, especially in cases with a large annulus; therefore, applying an additional stitch to the R-N commissure is extremely useful.