Related Experiment Video
Updated: Nov 11, 2025

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
Published on: July 5, 2016
Common-path interferometer for digital holographic Doppler spectroscopy of living biological tissues
Kwan Jeong1, Maria Josef Lopera2, John Turek3
1Korea Military Academy, Korea, Republic of.
Significance:
Common-path interferometers have the advantage of producing ultrastable interferometric fringes compared with conventional interferometers, such as Michelson or Mach-Zehnder that are sensitive to environmental instabilities. Isolating interferometric measurements from mechanical disturbances is important in biodynamic imaging because Doppler spectroscopy of intracellular dynamics requires extreme stability for phase-sensitive interferometric detection to capture fluctuation frequencies down to 10 mHz.
Aim:
The aim of this study was to demonstrate that Doppler spectra produced from a common-path interferometer using a grating and a spatial filter (SF) are comparable to, and more stable than, spectra from conventional biodynamic imaging.
Approach:
A common-path interferometer using a holographic diffraction grating and an SF was employed with a low-coherence source. Simulations evaluated the spatial resolution. DLD-1 (human colon adenocarcinoma) spheroids were used as living target tissue samples. Power spectra under external vibrations and drug-response spectrograms were compared between common-path and Fourier-domain holographic systems.
Results:
The common-path holography configuration shows enhanced interferometric stability against mechanical vibrations through common-mode rejection while maintaining sensitivity to Doppler frequency fluctuations caused by intracellular motions.
Conclusions:
A common-path interferometer using a grating and an SF can provide enhanced interferometric stability in tissue-dynamics spectroscopy for drug screening assays.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Two-Dimensional Microscopy in Microbiology

